WESA Automation
A technician with safety glasses inspecting a labeled control panel with a flashlight and clipboard

Panel Fabrication

Panels built and labeled to the standard your job calls for

WESA works to UL 508A, UL 698A, NNNY, CSA and NFPA 79. We build and label panels ourselves, so they reach your site ready for the inspector.

Which standard your panel is built to

Approvals keep moving when a panel arrives carrying a mark the authority having jurisdiction already recognizes. Without that mark, the corrections happen in the field after the panel is mounted.

The application decides the standard. Industrial control panels for general plant and machine use fall under UL 508A. Where the panel serves a hazardous location, UL 698A applies, and the UL NNNY category covers a panel installed directly in the classified area.

CSA requirements apply to equipment headed for Canadian jurisdictions or a customer who specifies the mark. NFPA 79 governs wiring methods, disconnects and safety circuits on industrial machinery. WESA builds to whichever standard a job calls for and documents it with the panel.

Because WESA applies the UL label rather than sending work out, the people who wire a panel are the same ones holding it to the listing requirements. That runs from component selection through the short-circuit current rating.

Standards we build to, and how we hold them

The five standards WESA works to, plus what keeps a panel inside the one it was built to.

UL 508A
Industrial control panels for general plant and machine use, built and labeled to UL 508A.
Hazardous locations (UL 698A and NNNY)
UL 698A is the general standard for industrial control equipment in hazardous-location applications. The UL NNNY category covers panels installed directly in the classified area. Which one applies depends on the area classification.
CSA
Panels built to CSA requirements for equipment headed for Canadian jurisdictions, or wherever a customer specifies the mark.
NFPA 79
The electrical standard for industrial machinery. Machine builds follow NFPA 79 for wiring methods, disconnects and safety circuits.
Listed components
Component selection starts with recognized and listed parts, so the assembly stays inside its rating.
Short-circuit current rating
The SCCR is set during design and documented with the panel, so the rating is clear at inspection.
UL labeling
WESA applies the UL label in-house, so a panel is not waiting on a third party before it ships.
Documentation that travels
Wiring diagrams and a bill of materials ship with every panel, so the record behind the standard stays with the equipment.

Need a panel built to UL, CSA or NFPA 79?